Aqua Lab MD3
Aqua Lab MD3

MD3

Manifold panel for up to (3) applications, pre-wired and plumbed for water, air, and chemical control. Includes (3) Pneumatic Actuated Stainless Steel Water Valves, (3) Air Valves, and (3) Air Regulators.

Power Requirements: 24VAC or 24VDC or 120VAC, 3.5 Watts Per Port
Dimensions: 6“D x 22“W x 29“H
Solution Outlet Lines: Up to 2.25 GPM (8.5 LPM) = 3/8“ ID (1/2“ OD Polyflow*), 3.25 - 4.25 GPM (13.3 - 17 LPM) = 1/2“ ID*, 5.5 GPM (20.8 LPM) = 5/8“ ID
Operating Water Pressure: 200 PSI (14 bar) Factory Set (Assumes 40 PSI (2.8 bar) City Feed)
Maximum Water Source Temperature: 140° F (60° C) with Booster Pump, 140° F (60° C) with Grundfos Pump
Water Filtration (Suggested): 50 Micron
Air Inlet Line: 3/8” OD Polyflow per MD Panel
Air Outlet Line: 3/8” OD Polyflow per Application
Air Inlet Pressure: 20 CFM at 80-120 PSI (5.5-8.3 bar) Dry Air

*Assuming line length is 50' (15 m) or less. Refer to user manual for recommended size chart for other lengths.

Voltage Part Number
24 VAC 1001577
24 VDC 1001578
120 VAC 1001579