Motor Control Unit (MCU) For Systems Without Air

For use with Aqua-Lab SDGEN2 Panels without air and 10 GPM (19 or 38 LPM) booster pumps.

NEW: Now equipped with a high-temp shutoff to protect and extend the life of your booster pumps.

Power Requirements:
10 GPM (38 LPM) Pump = 220V/1PH/60Hz/9A*

Dimensions: 8"D x 14" W x 16" H (20 x 36 x 41 cm)

*Recommended for use with a 15A breaker.

Voltage Part Number
24 VAC 1002964
24 VDC 1002965
120 VAC 1002960

SD GEN2 12/0 - No Air

Manifold panel for up to (12) applications (up to 3.75 GPM each valve or 7 GPM total).

INCLUDES:

·      (12) Integrated, Air-Actuated SAM Water Valves

Power Requirements: 24 VAC, 24 VDC, or 120 VAC
Dimensions: 8“D x 22“W x 17“H (20 x 56 x 43 cm)
Solution Outlet Lines: Up to 2.25 GPM (8.5 LPM) = 3/8“ ID (1/2“ OD Polyflow*), 3.25 - 4.25 GPM (13.3 - 17 LPM) = 1/2“ ID*
Operating Water Pressure: 200 PSI (14 bar) Factory Set (Assumes 40 PSI (2.8 bar) City Feed)
Water Source Temperature: MIN = 40º F (4º C), MAX = 137º F (58º C)
Water Filtration (Suggested): 50 Micron
Air Inlet Line: 3/8” OD Polyflow per SDGEN2 Panel
Air Outlet Line: 3/8” OD Polyflow per Application
Air Inlet Pressure: 20 CFM at 80-100 PSI (5.5-6.9 bar) Dry Air

*Assuming line length is 50' (15 m) or less. Refer to user manual for recommended size chart for other lengths.​

Voltage Part Number
24 VAC 1002960-24VAC
24 VDC 1002960-24VDC
120 VAC 1002960-120VAC

SD GEN2 9/0 - No Air

Manifold panel for up to (9) applications (up to 3.75 GPM each valve or 7 GPM total).

INCLUDES:

·      (9) Integrated, Air-Actuated SAM Water Valves

Power Requirements: 24 VAC, 24 VDC, or 120 VAC
Dimensions: 8“D x 22“W x 17“H (20 x 56 x 43 cm)
Solution Outlet Lines: Up to 2.25 GPM (8.5 LPM) = 3/8“ ID (1/2“ OD Polyflow*), 3.25 - 4.25 GPM (13.3 - 17 LPM) = 1/2“ ID*
Operating Water Pressure: 200 PSI (14 bar) Factory Set (Assumes 40 PSI (2.8 bar) City Feed)
Water Source Temperature: MIN = 40º F (4º C), MAX = 137º F (58º C)
Water Filtration (Suggested): 50 Micron
Air Inlet Line: 3/8” OD Polyflow per SDGEN2 Panel
Air Outlet Line: 3/8” OD Polyflow per Application
Air Inlet Pressure: 20 CFM at 80-100 PSI (5.5-6.9 bar) Dry Air

*Assuming line length is 50' (15 m) or less. Refer to user manual for recommended size chart for other lengths.​

Voltage Part Number
24 VAC 1002959-24VAC
24 VDC 1002959-24VDC
120 VAC 1002959-120VAC

SD GEN2 6/0 - No Air

Manifold panel for up to (6) applications (up to 3.75 GPM each valve or 7 GPM total).

INCLUDES:

·      (6) Integrated, Air-Actuated SAM Water Valves

Power Requirements: 24 VAC, 24 VDC, or 120 VAC
Dimensions: 8“D x 22“W x 17“H (20 x 56 x 43 cm)
Solution Outlet Lines: Up to 2.25 GPM (8.5 LPM) = 3/8“ ID (1/2“ OD Polyflow*), 3.25 - 4.25 GPM (13.3 - 17 LPM) = 1/2“ ID*
Operating Water Pressure: 200 PSI (14 bar) Factory Set (Assumes 40 PSI (2.8 bar) City Feed)
Water Source Temperature: MIN = 40º F (4º C), MAX = 137º F (58º C)
Water Filtration (Suggested): 50 Micron
Air Inlet Line: 3/8” OD Polyflow per SDGEN2 Panel
Air Outlet Line: 3/8” OD Polyflow per Application
Air Inlet Pressure: 20 CFM at 80-100 PSI (5.5-6.9 bar) Dry Air

*Assuming line length is 50' (15 m) or less. Refer to user manual for recommended size chart for other lengths.

Voltage Part Number
24 VAC 1002958-24VAC
24 VDC 1002958-24VDC
120 VAC 1002958-120VAC

Service Tech Parts Kit

Part Number
1002842

Chemical OEM Parts Kit

Part Number
1002841

Switchblade™ Nozzle Pills

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
Nozzle
Size
Part
Number
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
#1.0 1001780-010 .5 .6 .7 .8 .9 .9
#2.0 1001780-0​​20 1.0 1.2 1.4 1.6 1.7 1.8
#3.0 1001780-0​30 1.5 1.8 2.1 2.4 2.6 2.7
#4.0 1001780-0​40 2.0 2.4 2.8 3.2 3.5 3.6
#5.0 1001780-050 2.5 3.1 3.5 4.0 4.3 4.5
#6.0 1001780-0​60 3.0 3.7 4.2 4.7 5.2 5.4
#8.0 1001780-0​80 4.0 4.9 5.7 6.3 6.9 7.2
#10.0 1001780-100 5.0 6.1 7.1 7.9 8.7 8.9
#12.0 1001780-120 6.0 7.3 8.5 9.5 10.4 10.7
SST Plug 3000795 - - - - - -

#12.0 Switchblade Deuce™ Kit

#12.0 Switchblade Deuce Kit - Includes Switchblade Deuce Body, (2) 6.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
6.0 7.3 8.5 9.5 10.4 10.7
Nozzle Kit Part Number
1002035-120

#10.0 Switchblade Deuce™ Kit

#10.0 Switchblade Deuce Kit - Includes Switchblade Deuce Body, (2) 5.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
5.0 6.1 7.1 7.9 8.7 8.9
Nozzle Kit Part Number
1002035-100

#8.0 Switchblade Deuce™ Kit

#8.0 Switchblade Deuce Kit - Includes Switchblade Deuce Body, (2) 4.0 Nozzle Pills, And Stainless Steel Thread Tape ​​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
4.0 4.9 5.6 6.3 6.9 7.2
Nozzle Kit Part Number
1002035-080

#6.0 Switchblade Deuce™ Kit

#6.0 Switchblade Deuce Kit - Includes Switchblade Deuce Body, (2) 3.0 Nozzle Pills, And Stainless Steel Thread Tape 

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
3.0 3.7 4.2 4.7 5.2 5.4
Nozzle Kit Part Number
1002035-060

#4.0 Switchblade Deuce™ Kit

#4.0 Switchblade Deuce Kit - Includes Switchblade Deuce Body, (2) 2.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
2.0 2.4 2.8 3.2 3.5 3.6
Nozzle Kit Part Number
1002035-040

#2.0 Switchblade Deuce™ Kit

#2.0 Switchblade Deuce Kit - Includes Switchblade Deuce Body, (2) 1.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
1.0 1.2 1.4 1.6 1.7 1.8
Nozzle Kit Part Number
1002035-020

#14.0 Switchblade Quad™ Kit - (4334)

#14.0 Switchblade Quad Kit - Includes Switchblade Quad Body, (2) 4.0 Nozzle Pills, (2) 3.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
7.0 8.6 9.9 11.1 12.1 12.5
Nozzle Kit Part Number
1001929
Nozzle Rebuild Kit Part Number​
1002951-140

#12.0 Switchblade Quad™ Kit - (3333)

#12.0 Switchblade Quad Kit - Includes Switchblade Quad Body, (4) 3.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
6.0 7.3 8.5 9.5 10.4 10.7
Nozzle Kit Part Number
1002950
Nozzle Rebuild Kit Part Number​
1002951-120

#10.0 Switchblade Quad™ Kit - (3223)

#10.0 Switchblade Quad Kit - Includes Switchblade Quad Body, (2) 3.0 Nozzle Pills, (2) 2.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
5.0 6.1 7.1 7.9 8.7 8.9
Nozzle Kit Part Number
1001928
Nozzle Rebuild Kit Part Number​
1002951-100

#8.0 Switchblade Quad™ Kit - (2222)

#8.0 Switchblade Quad Kit - Includes Switchblade Quad Body, (4) 2.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
4.0 4.9 5.6 6.3 6.9 7.2
Nozzle Kit Part Number
1001927
Nozzle Rebuild Kit Part Number​
1002951-080

#6.0 Switchblade Quad™ Kit - (2112)

#6.0 Switchblade Quad Kit - Includes Switchblade Quad Body, (2) 2.0 Nozzle Pills, (2) 1.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
3.0 3.7 4.2 4.7 5.2 5.4
Nozzle Kit Part Number
1002949
Nozzle Rebuild Kit Part Number​
1002951-060

#4.0 Switchblade Quad™ Kit - (1111)

#4.0 Switchblade Quad Kit - Includes Switchblade Quad Body, (4) 1.0 Nozzle Pills, And Stainless Steel Thread Tape ​

Maximum Inlet Pressure: 3200 PSI (220 Bar)
Maximum Water Temperature: 180° F (+82° C)
Nozzle Tip Material: Tungsten Carbide
Connection Thread: 1/8” NPT

*Stainless steel thread tape is required for pill assembly.

Flow Rate Chart (GPM)
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3200
PSI
2.0 2.4 2.8 3.2 3.5 3.6
Nozzle Kit Part Number
1002889
Nozzle Rebuild Kit Part Number​
1002951-040

Smart Relay

  Description  Part Number
  24 VAC 1002894
  24 VDC 1002895
  120 VAC 1002896

Interface Fitting Assembly (XD Gen1)

  Part Number
  1002397

1/4” MBSP x 3/8” FNPT Adapter

  Part Number
  3000988

10 Pack Of Filter Inlet Screens

  Part Number
  1002884

10 Pack Of Dome Inlet Screens

  Part Number
  1002883

Interface Fitting Assembly - Legacy

  Part Number
  1001557

Push-To-Connect Airline Replacement Kit

Part Number
1002873

VFD Replacement - 7.5 HP

Part Number
230V - 1002665
460V - 1002667

VFD Replacement - 5 HP

Part Number
230V - 1002664
460V - 1002666

VFD Disconnect Switch & Handle Replacement Kit

Part Number
230V - 1002845
460V - 1002844

MCU Disconnect Switch & Handle Replacement Kit

Part Number
1002885

MCU Disconnect Switch & Handle (SD GEN2)

Part Number
1002886

Grundfos Pump System Manifold O-Ring

Part Number
3001878

5 or 10 GPM Pump Plumbing Assembly

Part Number
1002656

5 or 10 GPM Pump Plumbing With Inlet Selector

Part Number
1002655

5 GPM Pump Replacement (SD GEN2)

Part Number
3002481

10 GPM Pump Replacement (SD GEN2)

Part Number
30002482

1” Male Quick Connect - Brass

Part Number
3000205

1” Ball Valve

Part Number
3000509

Solenoid Coil Replacement For Air Actuated Valve (SD GEN2)

  Description  Part Number
  24 VAC 1002852
  24 VDC 1002853
  120 VAC 1002854

Primary Air Regulator Replacement Bowl (SD GEN2)

Part Number
1002862

Primary Air Regulator (SD GEN2)

Part Number
1002874

3 HP VFD Keypad

Part Number
3002589

3 HP VFD Shaft Pistol Handle

Part Number
1002930

3 HP VFD Relay Socket

Part Number
1002928

3HP Variable Frequency Drive Replacement

  Description  Part Number
  230V 1002926
  460V 1002927

3 HP VFD Power Supply

  Description  Part Number
  230V 1002924
  460V 1002925

Dual 3 HP Variable Frequency Drive (VFD)

EFFICIENT - Because a VFD adjusts the speed of the motor based on real-time site demands and system flow requirements, it can reduce related energy consumption and costs.

EXTENDS THE LIFE OF THE PUMP - Puts less wear and tear on the motor and results in cooler running pumps due to water not bypassing.

IMPROVED CHEMICAL CONSISTENCY - Tighter tolerances on a VFD eliminaet pressure fluctuations.

POTENTIAL LOCAL UTILITY REBATES - The federal government and many local utilities offer incentives and rebates when installing energy efficient devices like VFDs. Contact your local utility or check the national database at www.dsireusa.org.

Power Requirements: 230V/3HP/60Hz/8.9A or 460V/3HP/60Hz/4.2A
20 GPM Wall-Mounted Booster Pump: 12"D x 36"W x 48"H (31 x 91 x 122 cm)
20 GPM Floor-Mounted Booster Pump: 22"D x 32"W x 54"H (56 x 82 x 138 cm)
Water Inlet Lines: 20 GPM Booster = 1" ID
Operating Water Pressure: 200 PSI (14 bar) (Factory Set) - Assumes 40 PSI (2.8 bar) City Feed
Maximum Water Source Temperature: 140° F (+60° C)
Water Filtration (Suggested): 50 Micron
Maxiumum Ambient Temperature: 130° F (54°C)

VFD Only Site Voltage Control Voltage Part Number
Dual 230V 24 VAC 1002906
Dual 230V 24 VDC 1002907
Dual 230V 120VAC 1002908
Dual 460V 24VAC 1002903
Dual 460V 24VDC 1002904
Dual 460V 120VAC 1002905

Single 3 HP Variable Frequency Drive (VFD)

EFFICIENT - Because a VFD adjusts the speed of the motor based on real-time site demands and system flow requirements, it can reduce related energy consumption and costs.

EXTENDS THE LIFE OF THE PUMP - Puts less wear and tear on the motor and results in cooler running pumps due to water not bypassing.

IMPROVED CHEMICAL CONSISTENCY - Tighter tolerances on a VFD eliminaet pressure fluctuations.

POTENTIAL LOCAL UTILITY REBATES - The federal government and many local utilities offer incentives and rebates when installing energy efficient devices like VFDs. Contact your local utility or check the national database at www.dsireusa.org.

Power Requirements: 230V/3HP/60Hz/8.9A or 460V/3HP/60Hz/4.2A
20 GPM Wall-Mounted Booster Pump: 12"D x 36"W x 48"H (31 x 91 x 122 cm)
20 GPM Floor-Mounted Booster Pump: 22"D x 32"W x 54"H (56 x 82 x 138 cm)
Water Inlet Lines: 20 GPM Booster = 1" ID
Operating Water Pressure: 200 PSI (14 bar) (Factory Set) - Assumes 40 PSI (2.8 bar) City Feed
Maximum Water Source Temperature: 140° F (+60° C)
Water Filtration (Suggested): 50 Micron
Maxiumum Ambient Temperature: 130° F (54°C)

VFD Only Site Voltage Control Voltage Part Number
Single 230V 24 VAC 1002900
Single 230V 24 VDC 1002901
Single 230V 120VAC 1002902
Single 460V 24VAC 1002897
Single 460V 24VDC 1002898
Single 460V 120VAC 1002899

Single Booster for 3 HP VFD

Flow Rate: 20 GPM (75 LPM).

For use with 3 HP variable frequency drive (VFD).

ASSEMBLY CONFIGURATION:

  • (1) Active pump, for use with
  • (1) Water source

Power Requirements: 230V/3PH/60Hz/8.9A or 460V/3PH/60Hz/4.2A
20 GPM Wall-Mounted Booster Pump: 12”D x 36”W x 48”H (31 x 91 x 122 cm)
20 GPM Floor-Mounted Booster Pump: 22”D x 32”W x 54”H  (56 x 82 x 138 cm)
Water Inlet Lines: 20 GPM Booster = 1” ID
Operating Water Pressure: 200 PSI (14 bar) (Factory Set) (Assumes 40 PSI (2.8 bar) City Feed)
Maximum Water Source Temperature: 140° F (+60° C)
Water Filtration (Suggested): 50 Micron
Maximum Ambient Temperature: 130° F (54° C)

Wall-Mount

Site Voltage* Part Number
230V  1002909-230
460V  1002909-460

 

Floor Mount

Site Voltage* Part Number
230V 1002915-230
460V  1002915-460

 

*Other voltage options available. Contact Hydra-Flex for more information.

Single Booster w/ Backup for 3 HP VFD

Flow Rate: 20 GPM (75 LPM) (each pump)

For use with 3 HP variable frequency drive (VFD).

ASSEMBLY CONFIGURATION:

  • (1) Active pump, for use with
  • (1) Water source
  • (1) Back-up pump

Power Requirements: 230V/3PH/60Hz/8.9A or 460V/3PH/60Hz/4.2A
20 GPM Wall-Mounted Booster Pump: 12”D x 24”W x 48”H (31 x 61 x 122 cm)
20 GPM Floor-Mounted Booster Pump: 12”D x 32”W x 54”H  (31 x 82 x 138 cm)
Water Inlet Lines: 20 GPM Booster = 1” ID
Operating Water Pressure: 200 PSI (14 bar) (Factory Set) (Assumes 40 PSI (2.8 bar) City Feed)
Maximum Water Source Temperature: 140° F (+60° C)
Water Filtration (Suggested): 50 Micron
Maxium Ambient Temperature: 130° F (54° C)

Wall-Mount

Site Voltage* Part Number
230V  1002910-230
460V  1002910-460

 

Floor Mount

Site Voltage* Part Number
230V 1002914-230
460V  1002914-460

 

*Other voltage options available. Contact Hydra-Flex for more information.

Multi-Source Booster for 3 HP VFD

Flow Rate: 20 GPM (75 LPM) (each pump)

For use with 3 HP variable frequency drive (VFD).

ASSEMBLY CONFIGURATION:

  • (2) Active pumps, for use with 
  • (2) Water sources
  • (1) Back-up pump

Power Requirements: 230V/3PH/60Hz/8.9A or 460V/3PH/60Hz/4.2A
20 GPM Wall-Mounted Booster Pump: 12”D x 36”W x 48”H (31 x 91 x 122 cm)
20 GPM Floor-Mounted Booster Pump: 22”D x 32”W x 54”H  (56 x 82 x 138 cm)
Water Inlet Lines: 20 GPM Booster = 1” ID
Operating Water Pressure: 200 PSI (14 bar) (Factory Set) (Assumes 40 PSI (2.8 bar) City Feed)
Maximum Water Source Temperature: 140° F (+60° C)
Water Filtration (Suggested): 50 Micron
Maximum Ambient Temperature: 130° F (54° C)

Wall-Mount

Site Voltage* Part Number
230V  1002911-230
460V  1002911-460

 

Floor Mount

Site Voltage* Part Number
230V 1002916-230
460V  1002916-460

 

*Other voltage options available. Contact Hydra-Flex for more information.

Multi-Source Booster w/ Back-Up for 3 HP VFD

Flow Rate: 20 GPM (75 LPM) (each pump)

For use with 3 HP variable frequency drive (VFD).

ASSEMBLY CONFIGURATION:

  • (2) Active pumps, for use with 
  • (2) Water sources
  • (1) Back-up pump

Power Requirements: 230V/3PH/60Hz/8.9A or 460V/3PH/60Hz/4.2A
20 GPM Wall-Mounted Booster Pump: 12”D x 36”W x 48”H (31 x 91 x 122 cm)
20 GPM Floor-Mounted Booster Pump: 22”D x 32”W x 54”H  (56 x 82 x 138 cm)
Water Inlet Lines: 20 GPM Booster = 1” ID
Operating Water Pressure: 200 PSI (14 bar) (Factory Set) (Assumes 40 PSI (2.8 bar) City Feed)
Maximum Water Source Temperature: 140° F (+60° C)
Water Filtration (Suggested): 50 Micron
Maximum Ambient Temperature: 130° F (54° C)

Wall-Mount

Site Voltage* Part Number
230V  1002912-230
460V  1002912-460

 

Floor Mount

Site Voltage* Part Number
230V 1002917-230
460V  1002917-460

 

*Other voltage options available. Contact Hydra-Flex for more information.

Single Booster Rack Kit for MCU

EASY TO INSTALL - Simply slide the rack(s) in place - no wall mounting required (floor securing hardware is included). The Rack Mounting Kit holds any Aqua-Lab™ MDGEN2, XDGEN2, or HD panel with booster pump, motor controls, and basic tubing management. Systems are delivered pre-wired and pre-plumbed for water, air, and chemical control.

IDEAL FOR RETROFITS - Don't lose revenue by shutting down to make upgrades. The Rack Mount Kit allows live changeovers from legacy equipment, and its streamlined, compact design takes up less overall wall space.

CONFIGURABLE - Install panel racks in line to create a centralized chemical control station or space them out to strategically optimize your back room.

   Space Requirements
  34“D x 35“W x 71“H (87 x 89 x 181 cm)
  Description  Part Number
  Rack Mount Single Booster Pump 1001242
  Rack Mount Back-Up Pump 1001362

 

For site voltage of 230V or 460V. Other voltage options may be available. Contact Hydra-Flex for more information.

20 GPM Quick Connect Regulator Assembly
20 GPM Quick Connect Regulator Assembly

20 GPM Quick Connect Regulator Assembly

20 GPM quick connect regulator plumbing assembly.

Part Number
1002340
1/4” Push To Connect Tee
1/4” Push To Connect Tee

1/4” Push To Connect Tee

Part Number
3000815
Outlet Pressure Gauge 0-400 PSI - Bottom Mount
Outlet Pressure Gauge 0-400 PSI - Bottom Mount

Outlet Pressure Gauge 0-400 PSI - Bottom Mount

Part Number
3000491
Primary Air Regulator
Primary Air Regulator

Primary Air Regulator

Part Number
1001184
Solenoid Actuated Air Valve - Foaming
Solenoid Actuated Air Valve - Foaming

Solenoid Actuated Air Valve - Foaming

Voltage Part Number
24 VAC 1001428
24 VDC 1001429
120 VAC 1001430

Gasket & Screw Kit For Foaming Air Actuated Valve

Part Number
3002554

Bug Prep Pressure Switch Manifold

Part Number
1001558

1” Check Valve - Brass

Part Number
3000250

Outlet Manifold

Part Number
3000662

Pisco Regulator Replacement

Part Number
3000543

Pneumatic Replacement Valve with Regulator

  Description  Part Number
  24 VAC 1001274
  24 VDC 1001275
  120 VAC 1001276

M12 x DIN A Cable

Part Number
3000350

M12 x DIN A x DIN I Splitter Cable - Long

Part Number
3000408

M12 x DIN A x DIN I Splitter Cable - Medium

Part Number
3000407

M12 x DIN A x DIN I Splitter Cable

Part Number
3000406

Electric Solenoid Valve Replacement

  Description  Part Number
  24 VAC 1001072
  24 VDC 1001073
  120 VAC 1001074

1” Wye Strainer - 30 Mesh

Part Number
3000490

Manifold Inlet 1” ID Hose x 1” NPT Ends - 72” (1.8m) Long

Part Number
3001732

Manifold Inlet 3/4” ID Hose x 1/2” NPT Ends - 72” (1.8m) Long

Part Number
3000579

M12 Junction Block - 8 Port Homerun Cable

  Description  Part Number
  30' (10 m) 1002875
  100' (30 m) 1002876

1/4” Push to Connect to 1/8” NPT Elbow - Plastic

Part Number
3002033

BAM End Cap Kit

Part Number
1002395

MAM End Cap Kit

Part Number
1002507

BAM to MAM Coupler

Part Number
1002538

BAM Inlet Kit

Part Number
1002396

MAM Inlet Kit

Part Number
1002508
Foaming Small Air Regulator And 0-60 PSI Gauge
Foaming Small Air Regulator And 0-60 PSI Gauge

Foaming Small Air Regulator And 0-60 PSI Gauge

Part Number
1002872

Primary Air Regulator Replacement Bowl

Part Number
1002861

M12 x DIN I Cordset

  Description  Part Number
  24 VAC/DC 3001957
  120 VAC 3001958

BAM O-Ring Repair Kit

Part Number
1002222

MAM O-Ring Repair Kit

Part Number
1002751

BAM Valve Repair Kit

Part Number
1002223

MAM Valve Repair Kit

Part Number
1002752

Single BAM Valve Replacement

Part Number
1002216

Single MAM Valve Replacement

NOTE: Not compatible with MDGEN1 Hydra-Cannon.

Part Number
1002505

3/4” Check Valve (PC3)

3/4" FNPT x 3/4" FNPT check valve prevents the backward flow of fluid. For use with PC3 injectors only.

Part Number
3002091
Tri Foam Kit BAM
Tri Foam Kit BAM

Triple Foam Kit (BAM)

Three position quick-connect manifold that fits into a single Aqua-Lab port for dispensing three chemicals or colors to the same applicator. Also for use with foam applicators that use three foam generators. Kit includes (1) triple-foam manifold, (3) check valves, (3) 1/2" poly push-connect fittings, (3) anti-siphon devices, and (3) packs of standard metering tips. For use with PC2 injectors (not included).

Part Number
1002268
Duo-Foam Kit
Duo-Foam Kit

Duo-Foam Kit (MAM)

Two position quick-connect manifold that fits into a single Aqua-Lab port for dispensing two chemicals or colors to the same applicator. Also for use with foam applicators that use two foam generators. Kit includes (1) duo-foam manifold, (2) check valves, (2) 1/2" poly push-connect fittings, (2) anti-siphon devices, and (2) packs of standard metering tips. For use with PC2 injectors (not included).

Part Number
1001869

MD GEN2 7/9

Manifold panel for up to (7) applications (up to 6 GPM each valve or 28 GPM total).

INCLUDES:

  • (7) Integrated, Air-Actuated SAM Water Valves
  • (7) Air Pilot Valves
  • (9) Foaming Air Regualotrs + Valves

Power Requirements: 24VAC or 24VDC or 120VAC, 3.5 Watts/Port With Foaming Air
Dimensions: 7“D x 32“W x 34“H (18 x 81 x 86 cm)
Solution Outlet Lines: Up to 2.25 GPM (8.5 LPM) = 3/8“ ID (1/2“ OD Polyflow*), 3.25 - 4.25 GPM (13.3 - 17 LPM) = 1/2“ ID*, 5.5 GPM (20.8 LPM) = 5/8" ID, 10.0 - 15.0 GPM (37.9 - 56. 8 LPM) = 3/4" ID*
Operating Water Pressure: 200 PSI (14 bar) Factory Set (Assumes 40 PSI (2.8 bar) City Feed)
Water Source Temperature: MIN = 40º F (4º C), MAX = 137º F (58º C)
Water Filtration (Suggested): 50 Micron
Air Inlet Line: 3/8” OD Polyflow per Panel
Air Outlet Line: 3/8” OD Polyflow per Application
Air Inlet Pressure: 20 CFM at 80-100 PSI (5.5-6.9 bar) Dry Air

*Assuming line length is 50' (15 m) or less. Refer to user manual for recommended size chart for other lengths.

Voltage Part Number
24 VAC 1002732
24 VDC 1002736
120 VAC 1002740
MD GEN2 5/7
MD GEN2 5/7

MD GEN2 5/7

Manifold panel for up to (5) applications (up to 6 GPM each valve or 28 GPM total).

INCLUDES:

  • (5) Integrated, Air-Actuated SAM Water Valves
  • (5) Air Pilot Valves
  • (7) Foaming Air Regualotrs + Valves

Power Requirements: 24VAC or 24VDC or 120VAC, 3.5 Watts/Port With Foaming Air
Dimensions: 7“D x 32“W x 34“H (18 x 81 x 86 cm)
Solution Outlet Lines: Up to 2.25 GPM (8.5 LPM) = 3/8“ ID (1/2“ OD Polyflow*), 3.25 - 4.25 GPM (13.3 - 17 LPM) = 1/2“ ID*, 5.5 GPM (20.8 LPM) = 5/8" ID, 10.0 - 15.0 GPM (37.9 - 56. 8 LPM) = 3/4" ID*
Operating Water Pressure: 200 PSI (14 bar) Factory Set (Assumes 40 PSI (2.8 bar) City Feed)
Water Source Temperature: MIN = 40º F (4º C), MAX = 137º F (58º C)
Water Filtration (Suggested): 50 Micron
Air Inlet Line: 3/8” OD Polyflow per Panel
Air Outlet Line: 3/8” OD Polyflow per Application
Air Inlet Pressure: 20 CFM at 80-100 PSI (5.5-6.9 bar) Dry Air

*Assuming line length is 50' (15 m) or less. Refer to user manual for recommended size chart for other lengths.

Voltage Part Number
24 VAC 1002730
24 VDC 1002734
120 VAC 1002738

Solenoid Air Actuated Air Valve Replacement Kit

  Description  Part Number
  24 VAC 1002774
  24 VDC 1002775
  120 VAC 1002776

SAM Solenoid Actuated Air Valve - Foaming

  Description  Part Number
  24 VAC 1002849
  24 VDC 1002850
  120 VAC 1002851

High-Temp Light

  Description  Part Number
  24 VAC/DC 1002865
  120 VAC 1002866

SAM Bypass Pressure Regulator

Part Number
3002524

SAM Air Valve Cordset

Part Number
3002471

SAM Water Valve Cordset

Part Number
3002438

Zip Tie

Part Number
3002417